Cat 3 GD: Ex nA II T4: IP66 Plug and Socket ATEX Cat 3 compatiable for hazardous areas. CNOMO interface available in various materials.
• M20 x 1.5 conduit entry or 1/2” NPT
• Protection class IP66 according to ENBS60529 : 1992
• Connection by 2-pole 2.5mm2 terminal strip plus earth
• Continuously rated
• Maximum permitted voltage variation ±10%
• Maximum ambient temperature +60°C
• Low power consumption
• Wide range of voltages available
Non-incendive coil suitable for Zone 2 areas only, manufactured in accordance with the requirements of EN/IEC60079-15 and EN/IEC60079-31. Such that under normal operation it is not capable of
igniting a surrounding explosive atmosphere and a fault capable of causing ignition is not likely to occur. Covered by BASEEFA approval, Certificate Number BAS03ATEX0296X category Ex nA T4 and T6
(Type EP000/PS/N).